[[TitleIndustry]]

SAE J514 JIC fittings test specification

Date:Jun 09, 2019

For each size of SAE J514 JIC fittings, nine test assemblies in accordance with ISO 19879 shall be subjected to the proof test procedure specified in ISO 19879, prior to burst and cyclic endurance tests. They shall not leak at the respective proof pressures given in as follows:


Test pressures for steel and stainless steel 37° flared connections

Tube OD Working pressure  b Test pressures Metric  a Inch  Proof  Burst  Cyclic endurance

mm  in  MPa  (bar)  c MPa  (bar)  MPa  (bar)  MPa  (bar)

6  1/4  35  (350)  70  (700)  140  (1400)  46,6  (466)

8  5/16  35  (350)  70  (700)  140  (1400)  46,6  (466)

10  3/8  35  (350)  70  (700)  140  (1400)  46,6  (466)

12  1/2  31  (310)  62  (620)  124  (1240)  41,2  (412)

16  5/8  24  (240)  48  (480)  96  (960)  31,9  (319)

20  3/4  24  (240)  48  (480)  96  (960)  31,9  (319)

25  1  21  (210)  42  (420)  84  (840)  27,9  (279)

30 and 32  1 1/4  17  (170)  34  (340)  68  (680)  22,6  (226)

38  1 1/2  14  (140)  28  (280)  56  (560)  18,6  (186)

50  2  10,5  (105)  21  (210)  42  (420)  14  (140)

a Metric tubing shall be preferred.

b For working pressure applications higher than those given in Table 1, the manufacturer shall be consulted.

c 1 bar = 10 5 N/m 2 = 10 5 Pa = 0,1 MPa


Test pressures for copper alloy 37° ° flared connections

Tube OD Working pressure  b Test pressures Metric  a Inch  Proof  Burst  Cyclic endurance

mm  in  MPa  (bar)  c MPa  (bar)  c MPa  (bar)  c MPa  (bar)  c

6  1/4  20  (200)  40  (400)  80  (800)  26,6  (266)

8  5/16  20  (200)  40  (400)  80  (800)  26,6  (266)

10  3/8  16  (160)  32  (320)  64  (640)  21,3  (213)

12  1/2  16  (160)  32  (320)  64  (640)  21,3  (213)

16  5/8  12,5  (125)  25  (250)  50  (500)  16,6  (166)

20  3/4  12,5  (125)  25  (250)  50  (500)  16,6  (166)

25  1  10  (100)  20  (200)  40  (400)  13,3  (133)

30 and 32  1 1/4  8  (80)  16  (160)  32  (320)  10,6  (106)

38  1 1/2  6,3  (63)  12,6  (126)  25,2  (252)  8,4  (84)

50  2  5  (50)  10  (100)  20  (200)  6,7  (67)

The pressure values for copper alloy connectors and tubes were produced using brass connectors with phosphorescent soft-annealed copper tubing.

a Metric tubing shall be preferred.

b For working pressure applications higher than those given in Table 1, the manufacturer shall be consulted.

c 1 bar = 10 5 N/m 2 = 10 5 Pa = 0,1 MPa.



Previous: SAE J514 JIC fittings torque value specification

Next: SAE J514 JIC fittings specification for tubes